See this FAQ for more information. Last Modified By - Non-Electric Non-Gas Energy Meters is the person who last updated your property's energy meters (with the exception of electric and gas meters which are covered in separate metrics). To receive an ENERGY STAR score, a Worship facility must have at least 25 seats, but cannot have more than 4,000. Guiding Principle 3.2 Outdoor Water - Option 2. CBECS does not have a National Median for these 5 property types.
Gross Floor Area should include all space within the building(s) including workstations/hoods, offices, conference rooms, storage areas, decontamination rooms, mechanical rooms, elevator shafts, and stairwells. The energy that you generated and used does not count as âAvoided Emissionsâ because there were no emissions attributed to it from the beginning.
More details on Portfolio Views:
Individual monthly meter entry is more than 65 days long (only available for energy meters) - If any of your individual monthly meter entries is over 65 days, then you will not be able to get Weather Normalized Metrics. By default, all selections are set to Read Only. If portable classrooms have been added to your school, include the capacity of these classrooms, as they expand the overall capacity of your school. EUI stands for Energy Use Intensity.
If your property is in the design phase, use your best estimate for the intended conditions when the property is fully operational. Thermostats are set back if they are programmed to adjust at night and on weekends to a lower temperature in the heating months and a higher temperature in the cooling months. "
- The Date Meter became Active is the date (XX/XX/XXXX) of the very first bill for this meter (when the meter was installed or the date you want to start tracking your bills). Metrics in Portfolio Manager are calculated based on your energy data and Property Use Details (hours of operation, number of computers, etc.) Custom Access allows you to select more granular permissions for each group of information (Property, Meters, Goals, and Recognition). Areas not in enclosed buildings, such as outdoor habitats, open-air theaters, walkways, and landscaped areas should not be included in the Gross Floor Area. Social/Meeting hall refers to buildings primarily used for public or private gatherings. These estimated values are entered as annual totals for each energy type, so that a design project can be evaluated and compared with the Design Target and/or later with the propertyâs operational Source Energy. They bring expertise and achievement to building owners/managers seeking to benchmark and earn ENERGY STAR certification for their properties. The Number of Rooms is the total number of rooms at the property, including occupied rooms, non-occupied rooms, rooms in the process of being renovated and rooms for permanent house/administrative use. Other-Mall refers to buildings containing a collection of stores whose purpose is the sale of goods, but which do not fit into the enclosed mall, lifestyle center, or strip mall property types.
Gross Floor Area should include all space within the building(s), including retail stores, offices, food courts, restaurants, storage areas, staff break rooms, walkways, stairwells, and mechanical areas. Common reasons for not being eligible include:- Your property is not able to earn a 1-100 score
- You do not have an ENERGY STAR score of 75 or higher
- You have already earned ENERGY STAR certification within the last 11 months
- Your energy data is more than 120 days old
Specifically, the intent of this Guiding Principle is to:
Per the Energy Policy Act of 2005 (EPAct2005) Section 103, install building level electricity meters to track and continuously optimize performance. Change in EUI for an Energy Project compares the EUI value before and after an energy upgrade (or series of upgrades). The footprint of the race track itself should also be included in the gross floor area, along with the footprint of any staging areas. Number of Workers on Main Shift may include employees of the property, sub-contractors who are onsite regularly, and volunteers who perform regular onsite tasks. Total Waste (Disposed & Diverted) is the grand total of all the waste and materials that you are tracking. Cooling Equipment Redundancy describes the redundant capacity of the cooling equipment in a Data Center. For example, the person could view your energy usage but could not make corrections or add new energy bills.
Specifically, the intent of this Guiding Principle is to:
Receive an ENERGY STAR score of 75 or higher. Estimates are applied to all data centers in Canada.
The ENERGY STAR score for Senior Care Community applies to nursing homes (skilled nursing facilities) and assisted living facilities and is not intended for retirement communities that offer only independent living â a community with only independent living should benchmark under the Multifamily property use. Buildings that include one or more indoor ice sheets used for public or private, recreational or professional skating, hockey, or ringette. EUI enables you to compare different sized buildings. There are 4 exceptions to this rule when you should create a separate Property Use:- If it is a Property Use Type that can get an ENERGY STAR Score (note: Retail can only get a score if it is greater than 5,000 square feet)
- If it accounts for more than 25% of the property's GFA
- If it is a vacant/unoccupied Office
- Minneapolis Building ID
- Kansas City Building Reporting ID A use for this file might be a 3rd party vendor who offers energy consulting services and can upload your file to offer you efficiency recommendations.
As a future enhancement, we are considering adding Upload My Data to Portfolio Manager (where you would download the Green Button file from your utility, and upload it into Portfolio Manager. Portfolio Manager does not automatically populate this date.
- California Building ID
Specifically, the intent of this Guiding Principle is to:
Choose one of two options to meet additional daylighting and lighting controls performance expectations (minimum daylight factor or occupant controlled lighting), Guiding Principle 4.6 Indoor Environment - Integrated Pest Management. electricity or natural gas). Onsite Renewable Systems are electric generation systems located at your property that produce Green Power. It is also a valuable tool for evaluating the sustainability of non-government buildings.
Specifically, the intent of this Guiding Principle is to:
Use an integrated team to develop and implement policy regarding sustainable operations and maintenance. It was first developed for US federal building managers for compliance with the Federal Guiding Principles for High Performance Sustainable Buildings. Louis Building ID There are four main types of Property IDs: Property relationships describe the connection between two buildings.
- Water Use (All Water Sources) â sum of all water meters
- Indoor Water Use (All Water Sources) - sum of all Indoor water meters
- Outdoor Water Use (All Water Sources) - sum of all Outdoor water meters
- Municipally Supplied Potable Water - Total Use (All Meter Types) - sum of all Municipally Supplied Potable Water meters
- Municipally Supplied Reclaimed Water -Total Use (All Meter Types) - sum of all Municipally Supplied Reclaimed Water meters
- Well Water - Total Use (All Meter Types) - sum of all Well Water meters
- Other Water Sources - Total Use (All Meter Types) - sum of all Other Water meters
- Water Use Intensity (All Water Source) â all water sources divided by the building sq. Fixed Film Trickle Filtration Process is entered as either Yes or No. Meters must be installed before the application can be completed so that the LP reviewing the application may verify that the meters are in place. Parking structures may be free standing or physically connected to the property. Single Store is entered as either Yes or No.
- Yes â The property is a single store.
- No â The property contains two or more stores.
- âYour Choiceâ Year is a 12-month period which you select. Yes - Estimates for energy consumption will be applied for this data center. "
- Avoided Emissions â Onsite Green Power occur when you export energy from your onsite renewable electric system to the grid and youâve retained the RECs. The data will appear on a separate tab in your final report. ENERGY STAR Certification - Year(s) Certified (Score) is a list of all years for which your property has been certified. This count does not include newborn bassinets, labor room, post anesthesia, or postoperative recovery room beds, psychiatric holding beds, and beds that are used only as holding facilities for patients prior to their transfer to another hospital/inpatient facility.
If your property is in the design phase, use your best estimate for the intended conditions when the property is fully operational. The purpose is to empower customers with data. BOD5 is a commonly used determinant of the organic strength of a waste, recording the oxygen demand over a five-day period. Note that an administrative office occupied by a utility should be entered as Office, and a power or energy generation plant should be entered as Energy/Power Station. It must be entered in Million Gallons per Day (MGD).
If your property is in the design phase, use your best estimate for the intended conditions when the property is fully operational. For communities with apartment-type living units each apartment is considered a single unit. Examples of tertiary care include: Level I trauma centers, highly specialized medical care such as organ transplant centers or prenatal/neonatal intensive care centers. - No â The hospital does not provide tertiary medical care.
Gross Floor Area should include all space within the building(s), including circulation rooms, storage areas, reading/study rooms, administrative space, kitchens used by staff, lobbies, conference rooms and auditoriums, fitness areas for staff, storage areas, stairways, and elevator shafts. The Average Number of Residents is the average number of residents that occupied the property for the previous 12 months. You enter this value into Portfolio Manager whenever you create a multi-building property.
Please note that this value is not the number of buildings that have been individually benchmarked on a multi-building property. Cooling Equipment Redundancy describes the redundant capacity of the cooling equipment in a Data Center. At this time, the licensed professional is required to be a Professional Engineer (PE/P.Eng) or Registered Architect.
- A Professional Engineer (PE/P.Eng) is an engineer who is registered or licensed within certain jurisdictions (usually a state) to offer professional engineering services directly to the public. When you share a property, you determine the specific information that is shared and the specific actions that can be performed on the property. This is not a total count of workers, but rather a count of workers who are present at the same time. CDD is calculated in this way for each day of the year and summed up to get the total annual CDD.
- Owner Contact is the person who represents the property owner. If you choose to track at both of these levels, then you have a "parent-child" relationship: The property type indicates the single, primary use of your property.